Insulation Resistance Test
What is the Insulation Resistance Test.
The Insulation Resistance test is carried out as part of PAT Testing. This checks there is enough insulation between the live parts of the appliance and the metal parts which are touchable.
The Insulation Resistance Test is done for Class 1 and 2 Appliances. The Pass rate for Class 1 is 1 Million + Ohms and 2 Million + for Class 2.
To Carry out an Insulation Resistance test the Appliance must be switched on.
The cables are checked for any damage and wires must be connected in the plug before the Insulation Resistance test takes place.
Insulation Resistance Testing.
Visually check cables and appliance for Damage
Make sure Live, Neutral and Earth are Connected in Plug
Connect plug to PAT Tester
Switch Appliance on
Select Insulation Resistance Test
Pass if Class 1 Appliance is 1 M Ohm or more
Pass if Class 2 Appliance is 2 M Ohm or more
Record Results
PAT Testing
Kent, Essex and South East London.
You can contact us on.
Phone 01322 401499.
Mobile 07804 209078.
E-mail djhsounds@yahoo.com